实验室超声波清洗仪器使用方法及步骤

1、加入清洗液1. add cleaning fluid
在清洗槽内加入清水,并根据污垢性质添加适量的清洗剂。液体不宜太满或太少,能够浸没清洗物即可。如需开启加热功能,液面高度则不可低于内槽高度2/3。
add clean water into the cleaning tank and add an appropriate amount of cleaning agent according to the nature of dirt. the liquid should not be too full or too little. it can immerse the cleaning material. if the heating function needs to be turned on, the liquid level shall not be lower than 2 / 3 of the height of the inner tank.
2、放置清洗物
2. place cleaning materials
先将清洗物放置在清洗篮,而后同清洗篮一同放入清洗槽内,尽量不要直接将清洗物放置在清洗槽。
first place the cleaning materials in the cleaning basket, and then put them into the cleaning tank together with the cleaning basket. try not to directly place the cleaning materials in the cleaning tank.
3、开机
3. power on
正确连接电源插头,确保所供电源可靠接地。打开机器背面电源总开关(”0”表示关闭,"-"表示打开),开启后机器处于通电状态。
connect the power plug correctly to ensure the reliable grounding of the power supply. turn on the main power switch on the back of the machine (0 means off, - means on), and the machine will be powered on after it is turned on.
3.1 设置时间,启动超声
3.1 set the time and start the ultrasound
开机后时间显示为上次设置时间,按“设置”键一次,分钟显示数值闪烁,调节旋钮即可设置分钟。再按“设置”键一次,秒钟显示数值闪烁,调节旋钮即可设置秒钟。调节分钟、秒钟数值后,停止5秒时间设置完成。按“超声”键一次,启动超声波,再按一次,超声波暂停。
after power on, the time is displayed as the last set time. press the set key once, and the displayed value of minute flashes. adjust the knob to set the minute. press the setting key again, the displayed value will flash, and the adjustment knob can set for seconds. after adjusting the values of minutes and seconds, stop the 5-second time setting. press the ultrasonic key once to start the ultrasonic. press it again to pause the ultrasonic.
3.2 设置温度
3.2 setting temperature
开机后温度显示为上次设置温度,连续按“设置键,直至温度显示数值为闪烁状态,调节旋钮至所需温度后停止,5秒钟后温度设置完成。按“加热”键一次,启动加热功能,再按一次暂停加热,红色温度图标常亮。
after startup, the temperature is displayed as the last set temperature. press the set key continuously until the temperature display value is flashing. adjust the knob to the required temperature and then stop. after 5 seconds, the temperature setting is completed. press the heating key once to start the heating function, press it again to pause heating, and the red temperature icon is always on.
实验室超声波清洗仪器操作面板
laboratory ultrasonic cleaning instrument operation panel
4、频率切换、脱气功能
4. frequency switching and degassing function
4.1 频率切换(d系列双频机型)
4.1 frequency switching (only for d-series dual band models)
开机后频率显示为上次设置频率,按“频率”键一次即可切换频率。例如:28或45、45或80之间互相切换,具体需看使用何种机型。
after power on, the frequency is displayed as the last set frequency. press the frequency key once to switch the frequency. for example: switch between 28 or 45, 45 or 80, depending on which model is used.
4.2 脱气功能(d系列单频机型)
4.2 degassing function (only for d-series single frequency models)
按“脱气”键一次,启动脱气功能,仪器将以工作9秒停6秒的工作方式循环进行。此功能可将清洗时产生的空气排出,提升清洗效果。
press the degassing key once to start the degassing function, and the instrument will cycle in the working mode of working for 9 seconds and stopping for 6 seconds. this function can discharge the air generated during cleaning and improve the cleaning effect.
5、关机
5. shut down
按“超声”键一次,超声停止工作,关闭实验室超声波清洗仪器背部总电源开关,然后拔掉电源插头,排出清洗液,将内槽擦拭干净。
press the ultrasonic key once, the ultrasonic stops working, turn off the main power switch on the back of the laboratory ultrasonic cleaning instrument, then unplug the power plug, discharge the cleaning fluid, and wipe the inner tank clean.
关键词:清洗剂

5毫米聚乙烯四氟板价格/一平米多重
氧指数分析仪简介
【精度高售后好】邢台耐磨热电偶
样品或标准品“溢值”是什么原因造成的呢?
意大利MPFILTRI翡翠压差发讯器定义
实验室超声波清洗仪器使用方法及步骤
选择振飞厂家一体化雨水泵站的理由
数控铣床的工作方式
桥下干线护栏网
AGGB拖链电缆的使用特性是什么
2018年2月份传感器新品研发盘点
水果冷库在应用中应该注意什么,冷冻室温度多少合适?
《计量器具新产品管理办法》发布!规范计量器具新产品的型式批准管理
实验室玻璃器皿清洗洗瓶机对比手工
立式液下泵管道受损是由哪些原因导致的?
混凝土维勃稠度仪厂家适合范围
1200万美元!福特研发自动驾驶汽车决策系统
家用电器(电视机|冰箱|洗衣机|空调|微波炉|电磁炉|热水器|吸尘器...)国家标准(GB)一览表
果园施肥开沟机 开沟机价格
SEL微信保护装置451系列产品技术资料